The hotline
010-61738497
General electronic scale maintenance and electronic error reporting information
Beijing Hengbao after years of experience in the maintenance of electronic scales simple summary of the meaning of the loadometer electronic scale failure tips.
Electronic scales can not show no backlight when weighing?
1, the electronic scale internal program backlight function is not set (please refer to the operation manual settings).
2, set the backlight function, weighing pan need to be placed by the object (more than 9 times the amount of light can be).
3, may be electronic components failure.
Electronic scale display Err warning message?
Abnormal display instructions - the specific products of the manufacturers may be different
Display: [OU] indicates weighing> 100% F? S + 9 d
Display: [-FULL-] indicates weighing overload> 100% F? S + 30% F? S
Display: [-OU] indicates that the weighing is negative and the zero is too low
Display: [- OY--] indicates successful storage
Display: [- OY-1] indicates the number of cars. The number of tires recorded is equal to 200
Display: [- OY-2] indicates that the number of weighing records is over 1000
When the display: [-c-d- and - weighing value -], said the battery is insufficient, should be charged!
Display: [-OFF- -] indicates that the battery voltage is low until the meter is no longer working, please turn off the charge immediately!
Display: [Err 1] indicates that the A / D value is too low (less than -10% F? S)
Display: [Err 2] indicates that the A / D value is too high (greater than 100% F? S)
Display: [Err 3] indicates E2 PROM error
Beijing Heng standard professional maintenance of electronic scales, electronic scales, scales, hanging scales, if there is maintenance needs of electronic scales, please contact the standard technical hotline: 010-61732587